Seminal
The magazine and atlas of EU-funded researchA new publication from the web and AI team at Scott Charnley

Atlas / Ireland

Innovation Action · Running

EVOQUE Enhanced selectivity VOC detection using novel GC-QEPAS

Coordinator
Munster Technological University, Ireland
Runs
1 January 2024 to 30 June 2027
Status
Running
EU funding
€4.5m
Total cost
—
Partners
11 organisations in 3 countries
Type
Innovation Action
Grant agreement
101135764

What the project is doing

In the project's own words, from its summary on CORDIS.

Volatile organic compounds (VOCs) are organic chemicals that have a high vapor pressure at room temperature. Based on their origin and formation mechanisms, VOCs can be markers in many industrial processes; in food production as quality markers, technological indicators, process contaminants; in plant phenotyping as botanical/geographical tracers, authenticity markers; and in crops storage as shelf-life indicators. VOCs also pose a range of hazards to human health and the environment.

EVOQUE’s main objective is to develop a novel photonic-based sensory system with potential to outperform the current standards and to meet the challenging requirements of at-line, on-line & in-field needs of Agriculture, Food, Environmental Pollution monitoring and Industrial Emissions monitoring. EVOQUE will combine gas chromatography (GC), Quartz Enhanced Photo-Acoustic Spectroscopy (QEPAS), long wavelength quantum cascade lasers (QCLs) and mid-IR metasurfaces to produce a compact, easy to use, low cost, at-line and ultimately online, field deployable VOCs analyser that will have equivalent performance to the gold standard lab based GC-MS.

EVOQUE will leverage GC’s separation of components from complex mixtures, and QEPAS’s high sensitivity, specificity and quantification. Unlike simpler GC detectors, QEPAS will provide molecular recognition based on the specific spectral features of single VOCs. The system measures the target compound even in presence of interferents, thus avoiding issues with poor repeatability of elution times and reducing the false positive rate relative to GC with non-specific detectors.

Also, optical spectroscopy of many VOCs is hampered by absorption by atmospheric compounds at the wavelengths of interest or overlapping absorption features of related molecules; using the GC column, these compounds are separated and eluted from the column at different times, thus unleashing the potential of photonics for sensitive fast, non-destructive measurements of VOCs.

Topics

Who is involved

OrganisationCityCountryRole
Munster Technological UniversityCorkIrelandCoordinator
Centre National De La Recherche Scientifique CNRSParisFranceThird party
MirsenseOrsayFranceParticipant
Sra Instruments SASMarcy-l'EtoileFranceParticipant
TematysPalaiseauFranceParticipant
Universite De MontpellierMontpellierFranceParticipant
University College Cork - National University of Ireland, CorkCorkIrelandParticipant
Etg Risorse E Tecnologia SRLChivassoItalyParticipant
Illycaffe S.p.aTriesteItalyParticipant
Politecnico Di BariBariItalyParticipant
Universita Degli Studi Di TorinoTorinoItalyParticipant

Source: CORDIS, European Commission. Data of 5 Nov 2026, reused under the Commission's reuse policy. View on CORDIS · Grant DOI