Seminal
The magazine and atlas of EU-funded researchA new publication from the web and AI team at Scott Charnley

Atlas / Spain

Marie Skłodowska-Curie Action · Running

NanoNIR Development of a fluorescence-based nanotool for early breast cancer diagnosis

Coordinator
Universitat Politecnica De Valencia, Spain
Runs
1 September 2024 to 31 December 2027
Status
Running
EU funding
€201k
Total cost
—
Partners
3 organisations in 2 countries
Type
Marie Skłodowska-Curie Action
Grant agreement
101103902

What the project is doing

In the project's own words, from its summary on CORDIS.

Breast cancer is the most common cancer globally, accounting for 12% of all new annual cancer cases worldwide, according to the World Health Organization, and early detection is a key issue as survival improves when cancer is detected early. NanoNIR will develop a novel fluorescence-based nanotool for the detection and quantification of miR-99a-5p in liquid biopsy samples from breast cancer patients. The nanotool will consist of upconverting nanoparticles (UCNPs) decorated with aptamers and small gold nanoparticles (AuNPs).

UCNPs are inorganic nanocrystals that convert near-infrared (NIR) light into shorter wavelength emissions and exhibit narrow emission bandwidths and large anti-Stokes shifts (λex = 980 nm, λem = 540, 655 nm). These photophysical properties make them excellent candidates for fluorescence biosensing allowing for effective sensing with diminished background noise in a complicated detection system. The AuNPs have a large extinction coefficient and a broad UV–Vis absorption band (500 – 580 nm) making them excellent fluorescence quenching agents.

The combination of UCNPs (donors) with AuNPs (acceptors) linked through complementary aptamers will result in a fluorescence emission quenching of UCNPs at 540 nm. Following the detection of miR-99a-5p by its complementary aptamer sequence, AuNPs will be displaced from the UCNPs surface restoring the luminescence of UCNPs at 540 nm with an intensity-dependent to miRNA-9a-5p concentration allowing the detection of miR-99a-5p in real samples.

Additionally, the luminescence signal at 655 nm could be used for the ratiometric measurements.

Topics

Who is involved

OrganisationCityCountryRole
Universitat Politecnica De ValenciaValenciaSpainCoordinator
Universitaet RegensburgRegensburgGermanyAssociatedpartner
Fundacion Para La Investigacion Del Hospital Clinico De La Comunitat Valenciana, Fundacion InclivaValenciaSpainAssociatedpartner

Source: CORDIS, European Commission. Data of 5 Nov 2026, reused under the Commission's reuse policy. View on CORDIS · Grant DOI