Seminal
The magazine and atlas of EU-funded researchA new publication from the web and AI team at Scott Charnley

Atlas / United Kingdom

European Research Council grant · Running

TOUCHLESS Touchless Optical Ultraviolet CHemical resonantLy Enhanced Sensor Systems

Coordinator
University of York, United Kingdom
Runs
1 November 2026 to 31 October 2031
Status
Running
EU funding
€2.5m
Total cost
—
Partners
2 organisations in 2 countries
Type
European Research Council grant
Grant agreement
101267333

What the project is doing

In the project's own words, from its summary on CORDIS.

Imagine biosensor systems that can provide detailed information about your health, the environment or industrial processes, yet they can operate autonomously and non-invasively. They function without complex surface chemistries such as antibodies and can operate in a flow-through format, i.e. they work in a TOUCHLESS fashion. We will realise this exciting vision by opening up the field of ultraviolet (UV) nanophotonics, which is a true Frontier that is yet underexplored because it poses significant design challenges, it pushes the limits of nanofabrication and of materials.

UV nanophotonics enables a wide range of opportunities, because many molecules relevant for biomedical, industrial or environmental applications have strong signatures in the UV range. The PI and his team will use their unique combination of expertise in fundamental photonics, nanofabrication and instrumentation to pioneer novel structures that meet these challenges. We will explore three types of nanostructure-enhanced spectroscopy: 1.

Resonant mode Resonant Raman (R3) spectroscopy, which exploits the strongly enhanced Raman scattering in the UV with surprisingly little fluorescent background. Together with photonic resonances, we aim for a total enhancement factor of 108. 2. Integrated dispersion spectroscopy that uses phase to improve the sensitivity of absorption spectroscopy by 2 orders of magnitude. 3. Lensless fluorometry that uses flatband filters and compressive sensing to identify multiple fluorophores with a single UV LED while reducing cost and complexity by a factor 10-100.Applications include biofilm typing, drinking water monitoring and the analysis of infectious bacteria.

What distinguishes our approach is that it solely relies on the spectroscopic signature of the target molecules, so no recognition molecules are required. The methods are truly “touchless”-no surface attachment or complex sample processing is needed-so they can be readily used in a flow-through format.

Topics

Who is involved

OrganisationCityCountryRole
University of YorkYork North YorkshireUnited KingdomCoordinator
Phutung Research InstituteKathmanduNPParticipant

Source: CORDIS, European Commission. Data of 5 Nov 2026, reused under the Commission's reuse policy. View on CORDIS · Grant DOI